The Pentra C400 is a compact, fully automated clinical chemistry analyzer designed to perform both routine and specialty tests on a single system. It handles up to 55 onboard assays, offers continuous sample loading, and supports high efficiency with optional ion-selective electrode (ISE) capabilities—perfect for mid- to high-throughput laboratory settings.

Why Choose Pentra C400

  • Broad Test Menu – Features up to 55 assays onboard for comprehensive coverage.

  • High Throughput – Processes up to 420 tests/hour with the optional ISE module.

  • Continuous Loading – Efficient sample processing with 6 racks and barcode-based identification.

  • Smart Reagent Management – Cassettes with refrigerated storage and automated monitoring ensure reliability.

Why Choose

Technical Specifications of Pentra C400

General Description

  • Analysis Method Types:
    • Spectrophotometry: Colorimetry and Turbidimetry
    • Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)
  • Up to 55 assays on board
  • Optional ISE Module (Na+, K+, Cl-)
  • Maximum Throughput: 420 test/h
  • CE Marked

 

Sample Handling

  • Sample Capacity: 6 racks with 10 sample positions for primary tubes or cups
  • Continuous loading
  • Positive Sample Identification: Integrated Barcode Reader and Tube Presence Detector
  • Sample Integrity:Level, Shock and Clot Detection
  • Sample Collection Format: 0.7, 4, 5, 7 and 10 mL (diameter: 16mm)
  • Sample Specimen: Serum, Plasma, Urine, CSF, Whole Blood, Homogeneous Fluids
  • Sample Volume: 2 to 380 µL
  • Automatic Sample Dilution: from 1/2 to 1/22,500
  • ISE: 20 µL (Indirect) or 60 µL (Direct)
  • Automatic Post Concentration: from x2.0 to x 10.0
  • Automatic Re-run

 

Calibrator/Control Handling

  • Calibrator/Controls Positioning on Sample or Reagent Tray
  • Automatic Standard Dilution Series:
    • Dilution Factors: Main Direct 1/2 - 1/150
    • Dilution Factors: Main Indirect 1/2 - 1/1508

 

Reagent Handling

  • 52 Reagent positions on board:
    • 44 in a closed refrigerated area (2-10°C)
    • 8 at room temperature
  • Positive Reagent Identification:Integrated Barcode Reader
  • Reagent Probe : Level Detection and Preheating
  • Reagent Management with Cassettes: Automated Reagent On-board Stability Check plus Test Countdown with automatic back-up
  • Reagent Volume: from 2 to 600 µL

 

Reaction System

  • Reaction Volume: 150 to 600 µL
  • Reaction Temperature: Air bath at 37°C
  • Photometer Reaction Cycle:12 seconds
  • Mixing with Teflon-coated Stirrer
  • Reaction Time:  1 to 100 cycles
  • Disposable Acrylic Cuvettes
  • Automatic Cuvette Changer
  • Cuvette Capacity:  36 segments (432 cuvettes)
  • 7 Integrated Calculation Algorithms

Related Products

Yumizen C600

Yumizen C600

Automated Clinical Chemistry Analyzer

Yumizen C150

Yumizen C150

Automated Clinical Chemistry Analyzer

Yumizen CA40

Yumizen CA40

Semi-automated Clinical Chemistry Analyzer

Yumizen E60

Yumizen E60

Electrolyte Analyzer

Pentra C400

Pentra C400

Clinical Chemistry Analyzer

Pentra C200

Pentra C200

Clinical Chemistry Analyzer

NOT SURE WHAT YOU ARE LOOKING FOR?

BOOK A CONSULTATION

Our experts are here to guide you to the right solution. Fill out the form and we'll get in touch shortly.

*
*
*
*
*