Partica LA-960V2
Laser Scattering Particle Size Analyzer
The Partica LA-960V2 is a high-performance laser diffraction particle size analyzer, offering exceptional accuracy, rapid measurements, and unmatched repeatability. It supports both wet and dry measurement modes with advanced dispersion systems, delivering reliable and reproducible results for particle sizes ranging from nanometers to millimeters.
Why Choose Partica LA-960V2
Unmatched Accuracy – Measures particle size with precision up to ±0.6% using NIST-traceable standards.
-
Consistent Reproducibility – Maintains instrument-to-instrument consistency regardless of location or operator.
-
Fast, Automated Alignment – Computer-controlled laser alignment completes in just seconds.
-
Versatile Dispersion Systems – Fully automated wet and dry setups offer one-touch operation with consistent dispersion quality.

Key Advantages of Partica LA-960V2
High accuracy
minimizes measurement uncertainty
Rapid wet analysis
maximizes lab throughput
Automated dry dispersion
ensures reproducible dry measurements
Broad size range
accommodates diverse sample types
Applications of Partica LA-960V2
Paint and coatings optimization
ensures pigment dispersion stability
Cosmetic cream and lotion quality
monitors particle consistency
Airborne particulate monitoring
assesses PM in environmental studies; Mineral processing control — optimizes grind size for material efficiency
Technical Specifications of Partica LA-960V2
Laser scattering particle size distribution analyzer Model: LA-960V2
Measurement Principle | Mie scattering and Fraunhofer diffraction |
---|---|
Measurement Range | 10 nm - 5000 μm (Option dependent) |
Measurement Time | Typical measurement takes 60 seconds from liquid filling, sampling and measurement to rinsing. |
Measurement Method | Circulation measurement or fraction cell measurement (Fraction cell is optional) |
Sample Quantity | Approximately 10 mg - 5 g (Depending on the particle size, distribution and density) |
Dispersing Volume | Approximately 180 mL for standard pumping system, 5/10/15 mL for Fraction Cell accessory, Manual filling : 35 mL, Automatic filling : 40 mL for MiniFlow accessory. Approximately 1 L of LiterFlow option. |
Compatible Liquids | A type: Water*, S type: Common organic solvents (*also, mixtures with small volumes of ethanol) |
Communication | USB 2.0 (USB 3.0 required for some options) |
Light Sources | Red solid state 5 mW laser diode (650 nm), Blue solid state 3 mW LED (405 nm) |
Dispersion System | In-line ultrasonic probe: 30 W, 20 kHz, adjustable levels |
Operating Conditions | 15〜35°C (59 to 95°F), relative humidity 85% or less (no condensation) |
Power | AC 100-240V 50/60Hz, 300VA |
Dimensions | 705 (W) × 565 (D) × 500 (H) mm |
Mass | 54 kg |
Computer Requirements | Windows PC with available USB ports, Windows 10 64-bit or Windows 11 64-bit. Contact for additional details. |
※Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
PowderJet Dry Feeder Accessory
Dispersion Method | Compressed air dispersion using Venturi nozzle |
---|---|
Sample Delivery | Vibrating feeder |
Sample Disposal | Vacuum-driven evacuation |
Measurement range | 100 nm - 5000 μm |
Controls | Communication: Serial cable to LA-960V2 main unit |
Measurement Time | Typical measurement takes 2 seconds or longer. |
Operating Conditions for PowderJet | 15〜35°C (59 to 95°F), relative humidity 85% or less (no condensation) |
Dimensions | 332 (W) × 321 (D) × 244 (H) mm (not including dimensions of projections and LA-960V2 measurement unit) |
Power for PowderJet Operation | AC 100V, 120V, 230V, 50 or 60Hz, 1500VA (Including vacuum but LA-960V2 measurement unit) |
Compressed Air Supply Pressure | Compressed air supply origin pressure: 0.4 - 0.8 MPa |
Compressed Air Connection | Quick connector for resin tube with 6 mm outer diameter |
Remarks | Vacuum is equipped as standard |
※When ordering the PowderJet, please specify the power requirements for the final destination.
※Above specifications and functionality are valid only when PowderJet is installed on the LA-960V2 main unit and controlled using the LA-960V2 software.
※Manufacturers and models indicated for vacuum, air compressor, computer, monitor, and/or printer are subject to change.
◎Air Compressor
Inlet pressure within 0.5 - 038 MPa, Tank capacity 26 L or larger, Flow rate 45 L/min or faster
LY-9610 Imaging Unit
Observed Measurable Range for image analysis | 5 μm - 1000 μm* *5 μm for size and 9 μm for shape as per ISO 13322-2. |
---|---|
Pixel Size | 0.8 μm |
Speed | ≧ 4 fps |
Functions | Histogram of equivalent circle diameter. Shape Parameters: Aspect ratio*, Circularity*, Length*, Width* Trend graph of equivalent circle diameter. Post Analysis of captured image (zoom-in/out, measuring size). |
Communication | USB 3.0 |
*Optional Advanced software
Accessories
Components | LA-960N2 | LA-960A2 | LA-960S2 | LA-960W2 | LA-960L2 | |
---|---|---|---|---|---|---|
Optics | Standard optical system | • | • | • | • | • |
Aqua type Ethanol can be used as a dispersing additive. (0.01 - 3000 μm) | Standard circulation system | - | • | - | - | - |
Pressurized fill adapter | - | - | - | • | - | |
Liter flow | - | - | - | - | • | |
Peristaltic pump system | - | - | - | • | - | |
Solvent type(0.01 - 3000 μm) | Standard pump system | - | - | • | - | - |
Accessories | Fraction cell holder | • | • | • | • | • |
Mini-Flow with ultrasonic unit (0.01 - 1000 μm) | • | • | • | • | • | |
Paste cell holder | • | • | • | • | • | |
Dry unit (0.1 - 5000 μm) | • | • | • | • | • | |
Auto sampler | - | • | • | • | • | |
High Concentration Cell | • | • | • | • | • | |
Imaging Analysis Unit | - | • | • | • | • |
External Dimensions (mm)
Related Products
NOT SURE WHAT YOU ARE LOOKING FOR?
BOOK A CONSULTATION