Microsemi CRP LC-767G
Discover cutting-edge performance and reliability with our flagship product.
This new generation analyzer Microsemi CRP LC-767G is more compact and proposes enhanced software and network connectivity providing higher memory, usability plus a new ratio: Granulocytes-to-Lymphocytes Ratio (GLR).
The Microsemi CRP LC-767G provides information of great clinical value enabling quicker and more accurate medical decisions at the Point of Care to ultimately reduce hospitalization times and patient costs.
Its powerful and accurate CRP analysis allows the screening of patient samples to quantify the presence of inflammation caused by bacterial, viral (e.g. COVID-19), parasites infections (e.g. Malaria) and other treatable inflammatory diseases.
Why Choose Microsemi CRP LC-767G
- CBC+CRP results from whole blood in just 4 minutes
- Point of Care requiring just 10μL for CBC and 18μL for CBC+CRP
- CRP Measurement - Immunoturbidimetry technology for rapid and accurate diagnosis.

Key Advantages of Microsemi CRP LC-767G
CBC + CRP
Delivers combined results in just 4 minutes
CBC Only
High-throughput: 55 samples/hour supported.
Sample Volume
Minimal sample for CBC+CRP results
Parameters
All essential hematological parameters included.
Applications of Microsemi CRP LC-767G
Government Hospitals & Medical Colleges
High‑throughput hematology workflows with academic training modules and centralized digital records for large‑scale patient screening and research.
Standalone Laboratories
Compact benchtop deployments enabling rapid CBC testing, local reporting, and optional cloud‑based result sharing for independent labs.
Corporate Hospitals & Level 5 Labs
Enterprise‑grade hematology infrastructure with standardized protocols, multi‑site connectivity, and compliance management for corporate healthcare networks.
Complete Digital Hematology Solutions
End‑to‑end automated platform featuring LIS integration, remote slide review, and real‑time analytics for fully digitized hematology operations.
Technical Specifications of Microsemi CRP LC-767G
Technical
Weight | 35 lbs / 16 kg |
Power supply | 100 V to 240 V - 50 Hz to 60 Hz |
Dimensions | 16.9 in (h) x 8.7 in (w) x 17.3 in (d) / 430 mm (h) x 220 mm (w) x 440 mm (d) |
Printer | Built-in thermal printer |
Throughout | CBC + CRP: 15 tests/hour CBC: 55 tests/hour |
Data management | Complete QC menu, logs (reagents, calibration, maintenance, errors, blank cycle), easy operation Transmission of patient & QC results to LAN (local area network) USB memory External output RS-232C / Ethernet Mono-directional connection |
Memory | Result: 500 samples (with histogram) QC result: 180 samples / level (with histogram) |
Screen | LCD color touch screen |
Samples
60 samples/hour - Open tube | |
---|---|
Parameters (20) | CBC, WBC, RBC, RDW, HGB, MPV, HCT, MCV, PLT, MCH, MCHC, LYM# & LYM%, MON# & MON%, GRA# & GRA%, PDW*, PCT*, GLR Indicator |
Graphics | PLT, RBC, WBC curves |
Blood Volume | CBC + 3DIFF mode: 10 µL CBC + 3DIFF + CRP mode: 18 µL |
Stability | 48 hours post-draw stability |
Operating sample mode | Open tube |
Identification | Alphanumeric 16 digits UserID(OID) /SID/PID) Barcode reader (Accessories for all devices) |
* RUO parameters (Research Use Only)
Results
Parameters | Precision (cv %) | Linearity |
---|---|---|
WBC | < 2.5 (at 7.5 x 10³/µL) | 0-80 x 10³/µL |
RBC | < 1.5 (at 4.5 x 106/µL) | 0-7.5 x 106/µL |
HGB | < 1.5 (at 13.5 g/dL) | 0-23 x g/dl |
HCT | < 2.0 (at 35.%) | 0-65% |
PLT | < 5.0 (at 250 x 10³/µL) | 0-999 x 10³/µL |
CRP | < 10.0 (at 10.0 mg/L) | 0-200 mg/L (whole blood) |
CRP | < 8.0 (at 120.0 mg/L) |