ABX Pentra 60 C+
Hematology Analyzer
The ABX Pentra 60 C+ is a compact, closed‑tube benchtop hematology analyzer delivering routine CBC and 5‑part differential results. Leveraging DHSS and MDSS technologies, it ensures precise cell differentiation with only 4 onboard reagents and a single diluent. Featuring micro‑sampling (CBC: 30 µL / DIFF: 53 µL), 26 parameters, and intuitive software, it streamlines hematology workflows for small to mid-volume labs.
Why Choose ABX Pentra 60 C+
- Compact closed‑tube workflow enables safe, efficient processing with minimal sample handling.
- Small sample volume requires just 30 µL for CBC and 53 µL for CBC+DIFF, preserving precious specimens.
- Efficient reagent use with only four onboard reagents and one diluent reduces operational costs.
- Advanced cell differentiation via DHSS and MDSS yields accurate WBC subpopulation counting.

Key Advantages of ABX Pentra 60 C+
Compact Closed-Tube Operation
Enhances biosafety and workflow efficiency by reducing open-tube steps.
Low Sample Volume
Suitable for pediatric or low-volume specimens.
Low Reagent Consumption
Optimizes cost per test for routine hematology panels.
Precise 5-Part WBC Differential
Improves accuracy for leukocyte subpopulation analysis.
Technical Specifications of ABX Pentra 60 C+
Technical
Weight | 77 lbs / 35 kg | ||
Power supply | 100 to 240 V (± 10%) - 50 to 60 Hz. | ||
Dimensions | 20.3 x 17.5 x 19 in / 51,5 cm x 44,5 cm x 48 cm | ||
Printer | Laser printer | ||
Throughput | 60 tests/hour. | ||
Data management | Color screen: 15 in. monitor (800 x 600px) Windows XP Prof.TM User-defined flagging limits Transmit patient & QC to LIS Uni-directional or bi-directional connection Communication Protocols: ABX / ASTM CD-ROM drive / Floppy disk 2 serial ports minimum USB Keyboard / USB Mouse | ||
Memory | 10,000 results + Graphics | ||
Quality Control Management | 12 selectable QC files XB: 60 Operator selectable batches with statistics (20 samples per batch) Within run Levey-Jennings Graphs | ||
Logs | Reagents, calibration, maintenance, errors, blank cycle | |
Samples
60 samples/hour (closed tube) | |
---|---|
Parameters (26) | WBC, NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, ALY# & ALY%*, LIC# & LIC%*, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, PCT*, PDW*. |
Graphs | High-definition LMNE matrix |
Blood Volume | CBC mode : 30 µL |
Stability | 48 hours post-draw stability |
Operating sample mode | Closed tube |
Identification | Alphanumeric. Bar-code reader (optional) |
* RUO parameters (Research Use Only)
Results
Parameters | Precision (%CV) | Linearity |
---|---|---|
WBC | < 2.0 | 0-120 x 10³/µL |
RBC | < 2.0 | 0-8 x 106/µL |
HGB | < 1.0 | 0-24 g/dl |
HCT | < 2.0 | 0-67% |
PLT (whole blood) | < 5.0 | 0-1900 x 10³/µL |
PLT (PLT concentrate) | < 5.0 | 0-2800 x 10³/µL |
Reference | Description | |
---|---|---|
2062207 | ABX Difftrol - 2L + floppy | 2 x 3 mL vial |
2062203 | ABX Difftrol - 2N + floppy | 2 x 3 mL vial |
2062208 | ABX Difftrol - 2H + floppy | 2 x 3 mL vial |
2042208 | ABX Minotrol 16 - 2L | 2 x 2.5 mL vial |
2042209 | ABX Minotrol 16 - 2H | 2 x 2.5 mL vial |
2042202 | ABX Minotrol 16 - 2N | 2 x 2.5 mL vial |
Calibrators
Reference | Description | |
---|---|---|
2032002 | ABX Minocal | 1x2 mL |
N: normal level, H: high level, L: low level
* Recommended by HORIBA