ABX  Micros ES 60

Hematology Analyzer

The analyzer with a throughput of 60 tests per hour and requires only a 10 μL sample volume, making it suitable for neonatal and pediatric screening. It provides a CBC+Diff with 22 parameters and features a clinically suitable differential combination of LYM, MON, and GRA. The advanced PAMS technology flags conditions such as eosinophilia, blasts, NRBC, basophilia, and immature cells

 

Additionally, this analyzer is US FDA approved, ensuring high standards of quality and reliability. Advanced PAMS technology, real-time reagent management, comprehensive erythrocyte indices, and HL7 compatibility, ensuring high-quality results and efficient workflow management.

ABX  Micros ES 60

Why Choose ABX  Micros ES 60

  1. High Throughput: Processes up to 60 samples per hour 
  2. Comprehensive Parameters: Offers 22 parameters, including CBC+DIFF 
  3. Provides technology flags conditions such as eosinophilia, blasts, NRBC, basophilia, and immature cells. 
  4. CBC+ DIF mode: 10μL 
Why Choose

Key Advantages of ABX  Micros ES 60

1.

High Throughput

60 samples/hr

Ideal for high‑volume laboratories.

2.

Comprehensive Analysis

22 parameters

CBC+DIFF mode with 10 µL sample.

3.

Histogram Display

3 histograms

Visualize WBC, RBC & PLT distributions.

4.

Impedance & Photometry

Dual mode

Cell counts by impedance & cyanide‑free Hb photometry

Applications of ABX  Micros ES 60

Specialized Blood Analysis

Delivers in-depth evaluation of rare hematologic disorders using advanced flagging system.

Diagnostic Laboratories

Integrated sample tracking, QC features, and LIS connectivity for streamlined clinical workflows and regulatory compliance.

Outpatient Clinics

For quick and reliable blood tests in outpatient settings.

Hospitals

In critical care units, oncology departments, and emergency rooms for rapid and accurate blood analysis.

Pathology Laboratories

For routine hematology testing and differential analysis.

Technical Specifications of ABX  Micros ES 60

Technical

Weight:(OT) 30.9 lbs / 16 k, (CT) 35.7 lbs / 17 kg
Power supply:100 V to 240 V - 50 Hz to 60 Hz
Dimensions (HWD):(in) 16.9 x 14.2 x 14.2 / (cm) 43 x 36 x 36
Printer:

Built-in thermal printer

 

Throughput60 tests/hour (Open Tube)
Data Management:

Complete QC menu, logs (reagents, calibration, maintenance, errors, blank cycle), easy data transfer (USB), Transmission of patient & QC results to LAN (local area network), Mono-directional connection, All-in-one QC import, overlapping

Memory:1000 patients results with histograms
Screen:LCD colour touch screen (8.4")

Samples

Parameters (22)WBC LYM# & LYM% MON# & MON% GRA# & GRA%   RBC HGB HCT MCV   MCH MCHC RDW-SD* RDW-CV   PDW-CV*
PLT MPV PCT*   P-LCC P-LCR GLR
Graphics:PLT, RBC, WBC curves
Blood volume:CBC + 3DIFF mode: 10 μL
Stability:48 hours post-draw stability(at refrigerated temperature)
Operating sample mode:Open tube or Closed Tube
Identification:Alphanumeric, Integrated barcode reader
* RUO (Research Use Only)

Results

ParametersPresicion (cv %)Linearity
WBC< 2.5 (at 4 - 10.0 x 103/μL)0 - 100 x 10³/µL
RBC< 2.0 (at 4-7 x 106/μL)0 -8 x 106/µL
HGB< 1.5 (at 12-18 g/dL)0 - 26 x g/dL
HCT< 2.0 (at 36-54 %)0 - 80%
PLT (whole blood)< 5.0 (at 200-500 x103/μL)

0 - 2200 x 10³/µL (whole blood)

0 - 4000 x 10³/µL (PLT concentrate)

Blood Controls & Calibrators

Blood Controls

ReferenceDescription 
2042208ABX Minotrol 16 - 2L2 x 2.5 mL vial
2042202ABX Minotrol 16 - 2N2 x 2.5 mL vial
2042209ABX Minotrol 16 - 2H2 x 2.5 mL vial

Calibrators

ReferenceDescription 
2032002ABX Minocal2 mL vial

N: normal level, H: high level, L: low level
* Recommended by HORIBA

NOT SURE WHAT YOU ARE LOOKING FOR?

BOOK A CONSULTATION

Our experts are here to guide you to the right solution. Fill out the form and we'll get in touch shortly.

*
*
*
*
*
*
India
*
Type or select city
*
Select region
*
Sales
*
Select your segment
*

I agree to be contacted by HORIBA India/partners via call, SMS, WhatsApp, and email, and accept the Terms & Conditions and Privacy Policy