UV500
Online UV‑Visible Water Analyzer
The UV500 is an on‑line water analyzer with a high‑resolution 2048‑pixel UV‑visible spectrograph (180–750 nm) enabling simultaneous multi‑parameter monitoring (COD, BOD, TOC, NO₃, PO₄, colour, turbidity, Cr VI). Optional UV‑visible fluorescence for PAH detection, integrated nephelometric turbidity via laser diode, and a xenon flash lamp rated for >10⁹ flashes with automatic acid‑based cleaning ensure reliable, low‑maintenance operation in wastewater treatment, river monitoring, and chemical process control applications.
Why Choose UV500
- High‑Resolution Spectroscopy — 2048‑pixel spectrograph (180–750 nm) — Precise absorbance and spectral accuracy
- Simultaneous Multi‑Parameter Analysis — 8 metrics (COD, BOD, TOC, NO₃, PO₄, turbidity, colour, Cr VI) — Comprehensive water quality profiling
- UV‑Visible Fluorescence — Optional PAH detection module — Enhances contaminant screening
- Integrated Turbidity Measurement — Laser diode + dual‑wavelength compensation — Stable low‑level turbidity data
- Xenon Flash Lamp Longevity — >10⁹ flashes — Ensures over 10 years of continuous use
- Automatic Acid‑Cleaning — Built‑in cleaning cycle — Minimizes maintenance downtime

Key Advantages of UV500
Multi‑Parameter Monitoring
Effluent control in wastewater treatment
River Quality Surveillance
Environmental compliance
Drinking Water Safety
Ensures potability
Industrial Process Control
Chemical process optimization
Applications of UV500
Multi‑Parameter Monitoring
Multi‑Parameter Monitoring
Effluent control in wastewater treatment;
River Quality Surveillance
Technical Specifications of UV500
Online water analyzer, UV500 - Parameter specification
Parameter | Standard range Other ranges on request | Typical Repeatability For low values (<10% FS) | Accuracy On standard solution |
---|---|---|---|
UV254 | 0-200 Abs/m 0-600 Abs/m 0-2000 Abs/m | +/- 0.05 Abs/m +/- 0.15 Abs/m +/- 0.5 Abs/m | +/- 2% |
COD by UV correlation | 0-100 mg/l COD 0-2000 mg/l COD 0-20,000 mg/l COD | +/-0.05 mg/l COD +/- 1 mg/l COD +/- 10 mg/l COD | +/- 2% |
BOD by UV correlation | 0-100 mg/l BOD 0-1000 mg/l BOD 0-10,000 mg/l BOD | +/-0.05 mg/l BOD +/- 0.5 mg/l BOD +/- 5 mg/l BOD | +/- 2% |
TOC by UV correlation | 0-100 mg/l TOC 0-1000 mg/l TOC 0-10,000 mg/l TOC | +/-0.05 mg/l TOC +/- 0.5 mg/l TOC +/- 5 mg/l TOC | +/- 2% |
Ammonia | 0-100 mg/l NH4 | +/- 0.2 mg/l NH4 | +/- 5% |
Nitrate (NO3) | 0-100 mg/l NO3 | +/- 0.1 mg/l NO3 | +/- 2% |
Colour | 0-100 Pt/Co 0-1000 Pt/Co | +/- 0.2 Pt/Co +/- 2 Pt/Co | +/- 2% |
PAH (aromatics) | 0-10 mg/l C6H6 | +/- 0.01 mg/l C6H6 | +/- 2% |
Oil in Water | 0-100 ppm OIW 0-1000 ppm OIW | +/- 0.1 ppm OIW +/- 1 ppm OIW | +/- 2% |
Phosphate | 0-2 mg/l P-PO4 0-20 mg/l P-PO4 | +/- 0.01 mg/l P-PO4 +/- 0.1 mg/l P-PO4 | +/- 2% |
Hydrogen Sulphide | 0-20 mg/l H2S | +/-1 mg/l H2S | +/- 2% |
Chromium IV | 0-2 mg/l Cr VI | +/-0.04 mg/l Cr VI | +/- 2% |
Turbidity (TSS by correlation) | 0-10 NTU 0-100 NTU 0-1000 NTU | +/- 0.01 NTU +/- 0.1 NTU +/- 1 NTU | +/- 2% |
pH | 0-14 pH | +/- 0.01 pH | +/- 2% |
ORP | +/- 2000 mV | +/- 1 mV | +/- 2% |
Dissolved Oxygen(DO) | 0-25 mg/l O2 | +/- 0.1 mg/l O2 | +/- 2% |
Conductivity | 0-2000 μS | +/- 1 μS | +/- 2% |
External turbidity (TSS by correlation) | 0-4 NTU 0-40 NTU 0-400 NTU | +/- 2% +/- 2% +/- 2% | |
External TSS | 0-1500 mg/l TSS 0-30000 mg/l TSS | +/- 1% of reading or +/- 2 mg/l TSS +/- 1% of reading or +/- 2 mg/l TSS | |
Temperature | 0-80°C | +/- 0.1 °C | +/- 2% |
Online water analyzer, UV500 - General specification
Sample flow | Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S |
---|---|
Sample pressure | 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 – 0.5 Bar for NH4 or H2S |
Sample temperature | 0 °C to 80 °C 0°C to 30°C for NH4 or H2S |
Wet parts material | Quartz, Polypropylene, Polyethylene, FPM (Viton), PMMA (+ Pharmed and glass for NH4 or H2S) |
Measurement interval | 1 min to 720 min Physicochemical parameters may be continuous |
Memory | 5000 lines of measurements (up to 16 channels) with date and time |
Consumption | Cleaning solution (5% sulfuric acid): 220 ml/day Reagent for PO4: 2 ml per measurement NaOH 10% for NH4: 2 ml per measurement HCl 10% for H2S: 2 ml per measurement |
Maintenance interval | Recommended: 6 months to 1 year (except for refilling) |
Power supply | 90 - 264 VAC 50/60 Hz 80 VA |
Screen | Colour TFT LCD 640x480 pixels with LED backlight |
Communication | RS232 with MODBUS protocol RS485 for external probes (DO, TSS) USB WI-FI (IEEE802.11B) optional Ethernet (IEEE802.3) optional |
Certifications | CE, EN 61010-1, EN 61326e |
Enclosure | Stainless steel with epoxy coating, IP65, wall mounting brackets |
Dimensions | 525x345x260 mm |
Weight | 20 to 30 kg depending on the configuration |
UV500 Parts references
Basic Unit | |
---|---|
Sampling pump | |
pectrograph (required for UV254, COD, BOD, TOC, NO₃, Colour, PO₄, Cr VI, NH₄ and H₂S measurements) | |
Absorbance flow cell and xenon lamp (required for UV254, COD, BOD, TOC, NO₃, Colour, PO₄, Cr VI measurements) | |
Configuration and calibration for measurements by absorbance (require SPECTRO500 and ABS500 modules) | |
Measurement by UV fluorescence (required for PAH and OIW measurements) | |
Measurement module by colorimetric method (require SPECTRO500 and ABS500 module) | |
Measurement by nephelometry | |
Measurements by optical method | |
Measurement by UV absorption in gas phase | |
Input modules | |
Measurements by electrode (external) | |
Output modules | |
Recommanded consumables for 2 years : | |
UV500 | Basic unit (no measurement included Color graphic display 640x320 pixels with touch screen Built-in data logger, memory 5000 measurements for each parameter 12 sockets for input and output modules (not included, refer to options) 7 available glands for inputs / outputs RS232 included (Sub-D 9 ways female connector) with 2 meters cable for PC RS485 included for communication with MODBUS protocol USB port included for USB key connection Automatic cleaning system with 2 liters tank Power supply 90 - 264 VAC / maxi 100 VA : 50 - 60 Hz with power cord 2 meters Enclosure IP65/Nema4x stainless steel 316 521x473x250 mm (HxWxD) / 20 to 30 kg Mounting lugs for wall |
UV500-P (Premium) | Basic unit (no measurement included Same specifications as UV500 except dimensions : 525x473x260 mm |
P | Sampling peristaltic pump for unpressurized water Flow of about 940 mL/min Heavy duty brushless motor Discontinuous operating to increase tube lifetime |
P-EXT | External Peristaltic sampling pump for unpressurized water Built-in on the left side of the enclosure Flow of about 600 mL/min Discontinuous operating to increase tube lifetime |
SPECTRO500 | UV-Visible spectrograph Range: 180 – 750 nm Resolution 0.29 nm 2048 pixels |
ABS500 | Flow cell and xenon lamp for absorbance measurements Optical path: 1, 3 or 10 mm Lamp life time: 109 flashes Wet materials: PMMA, Viton, Quartz |
COD-H-500 | high range: 0 – 2000 Abs/m (equivalent to approx. 20000 mg/L COD on municipal waste water) |
COD-M-500 | Organic matter Medium range medium range: 0 – 600 Abs/m (equivalent to 2000 mg/L COD) |
COD-L-500 | Organic matter low range low range: 0 – 200 Abs/m (equivalent to 100 mg/L COD on river water) |
NO3-500 | Nitrate Range: 0 – 100 mg/L NO₃ (0 – 25 mg/L N of NO₃) Measurement possible until 250 mg/L NO₃ (60 mg/L N-NO₃) |
CO-H-500 | Colour high range Range: 0 – 1000 Pt-Co unit |
CO-L-500 | Colour low range Range: 0 – 100 Pt-Co unit |
PAH-500 | Poly-aromatic hydrocarbons Range: 0 – 10 ppm phenol Range: 0 – 100 ppm OIW (equivalent to approx. 0 – 100 ppm oil with 10% aromatic ratio) |
PO4-H-500 | Phosphate high range High range: 0 – 20 mg/L P (60 mg/L PO₄) Sampling peristaltic pump included |
CR6-500 | Hexavalent chromium (VI) Range: 0 – 2 mg/L Cr VI Measurement possible up to 5 mg/L Cr VI |
PO4-L-500 | Phosphate low range Low range: 0 – 2 mg/L P (6 mg/L PO₄) Sampling peristaltic pump included |
IRTURB-H-500 | Internal turbidity sensor high range High range: 0 – 1000 NTU Nephelometric method by laser diode at 650 nm (850 nm on request) |
IRTURB-M-500 | Internal turbidity sensor medium range Low range: 0 – 100 NTU Nephelometric method by laser diode at 650 nm (850 nm on request) |
IRTURB-L-500 | Internal turbidity sensor low range Low range: 0 – 10 NTU Nephelometric method by laser diode at 650 nm (850 nm on request) |
DO-F | Dissolved oxygen probe by fluorescence Range: 0 - 25 mg/L O₂ 7 meters of cable |
EXT-TURB-H | Turbidity probes high range High range: 0 – 30000 mg/L TSS 7 meters cable |
EXT-TURB-L | Turbidity probes low range Low range: 0 – 1500 mg/L TSS 7 meters cable |
EXT-TURBNEPH-H | Nephelometric turbidity probes high range Range: 0 – 400 NTU 10 meters cable |
EXT-TURBNEPH-M | Nephelometric turbidity probes medium range Range: 0 – 40 NTU 10 meters cable |
EXT-TURBNEPH-L | Nephelometric turbidity probes low range Range: 0 – 4 NTU 10 meters cable |
STRIP500 | Stripping system Include xenon lamp, flow cell, glassware, air pump, air filter and solenoid valve |
NH4-500 | Ammonia Range: 0 – 100 ppm NH₄+ |
H2S-500 | Hydrogen sulfide Range: 0 – 20 ppm H₂S |
IN4-20-500 | 4-20 mA input module Isolated 4-20 mA input Impedance: 100 Ohm |
LOGIC500 | Double logical inputs module Input no 1 : external pulse command for measurement Input no 2 : measurements inhibition Isolated 0 – 48 V DC inputs Impedance: >10 Kohm |
PH500 | pH/ORP module pH Range: 0 – 14 ATC input for platinum RTD 100 Ohm or 1000 Ohm ORP Range: -2000 mV to +2000 Mv |
COND500 | Conductivity module Range: 0 – 100 µS/cm to 0 – 100 mS/cm ATC input for platinum RTD 100 Ohm |
ELPH | pH on-line electrode Range: 0 – 14 5 meters of cable (10 meters in option) Built-in ATC RTD 100 Ohm |
ELORP | ORP on-line electrode Range: -2000 mV to +2000 Mv 5 meters of cable (10 meters in option) Built-in ATC RTD 100 Ohm |
ELCOND | Conductivity on-line electrode Range: 0 – 10 mS/cm Cell constant k=1.0 cm-1 (medium range) 5 meters of cable (10 meters in option) Built-in ATC RTD 100 Ohm |
ICOND | Inductive conductivity online probe Range: 0 – 100 mS/cm 3 meters of cable Built-in temperature compensation at 2.2%/°C Requires a IN4-20-500 module instead of COND500 module |
OUT4-20-500 | OUT4-20-500 Isolated 4-20 mA output Active output, Max load 500 Ohm |
RELAY500 | RELAY500 RELAY500 |
P-ACI-HD1 : | Head of cleaning pump (x1) |
P-RGT-HD1 : | Head of reagent pump (x1) (only for NH₄ or H₂S) |
T-PHAR-1 : | Tubing 6.4x9.6 mm (if optional sampling pump) (x2 to x8 depending on sampling pump use) |
Cleaning solution and reagents (if any) are not provided |
Online water analyzer, UV500 - Accessories
Sampling pump
Product code: P
Sampling peristaltic pump for unpressurized water
Built-in on the left side of the enclosure
Flow of about 0.6 litre/min
Discontinuous operating to increase tube lifetime
Sampling pump
Product code: P-EXT
External Peristaltic sampling pump for unpressurized water
Flow of about 940 ml/min
Heavy duty brushless motor
Discontinuous operating to increase tube lifetime
Input modules
Product code: IN4-20-500
4-20 mA input module
Isolated 4-20 mA input
Impedance: 100 Ohm
Input modules
Product code: LOGIC500
Double logical inputs module
Input no 1 : external pulse command for measurement
Input no 2 : measurements inhibition
Isolated 0 – 48 V DC inputs
Impedance: >10 Kohm
Output modules
Product code: OUT4-20-500
4-20 mA output module
Isolated 4-20 mA output
Active output, Max load 500 Ohm
Output modules
Product code: RELAY500
Relay module
Contact rating: 2A/220V
Communications
Product code: WIFI500
Wifi Interface
Connection to wireless WIFI network
Secured data transfer (WEP keys)
Communications
Product code: ETHER500
Ethernet interface
Ethernet 10 base-T (IEEE 802.3)
Secured data transfer (WEP keys)
Communications
Product code: MTI133
Phone modem
Industrial modem 33,6 Kb/s V34+
DIN rail Mounting
Power supply 24V from the analyser
Communications
Product code: GSM
GSM modem
Dual band (EGSM 900/1800 MHz)
Integral SIM card reader
R & TTE approved