UV500

UV500

Online UV‑Visible Water Analyzer

The UV500 is an on‑line water analyzer with a high‑resolution 2048‑pixel UV‑visible spectrograph (180–750 nm) enabling simultaneous multi‑parameter monitoring (COD, BOD, TOC, NO₃, PO₄, colour, turbidity, Cr VI). Optional UV‑visible fluorescence for PAH detection, integrated nephelometric turbidity via laser diode, and a xenon flash lamp rated for >10⁹ flashes with automatic acid‑based cleaning ensure reliable, low‑maintenance operation in wastewater treatment, river monitoring, and chemical process control applications.

Why Choose UV500

  1. High‑Resolution Spectroscopy — 2048‑pixel spectrograph (180–750 nm) — Precise absorbance and spectral accuracy
  2.  Simultaneous Multi‑Parameter Analysis — 8 metrics (COD, BOD, TOC, NO₃, PO₄, turbidity, colour, Cr VI) — Comprehensive water quality profiling
  3.  UV‑Visible Fluorescence — Optional PAH detection module — Enhances contaminant screening
  4. Integrated Turbidity Measurement — Laser diode + dual‑wavelength compensation — Stable low‑level turbidity data
  5.  Xenon Flash Lamp Longevity — >10⁹ flashes — Ensures over 10 years of continuous use
  6.  Automatic Acid‑Cleaning — Built‑in cleaning cycle — Minimizes maintenance downtime
Why Choose

Key Advantages of UV500

Multi‑Parameter Monitoring 

Continuous COD & BOD measurement

 Effluent control in wastewater treatment

River Quality Surveillance 

Real‑time turbidity & colour tracking

Environmental compliance

Drinking Water Safety

Inline nitrate, phosphate & Cr VI detection 

Ensures potability

Industrial Process Control

Simultaneous NO₃, PO₄ & turbidity monitoring 

Chemical process optimization

Applications of UV500

Multi‑Parameter Monitoring

Multi‑Parameter Monitoring

Effluent control in wastewater treatment;

River Quality Surveillance

Technical Specifications of UV500

Online water analyzer, UV500 - Parameter specification

ParameterStandard range
Other ranges on request
Typical Repeatability
For low values (<10% FS)
Accuracy
On standard solution
UV2540-200 Abs/m
0-600 Abs/m
0-2000 Abs/m
+/- 0.05 Abs/m
+/- 0.15 Abs/m
+/- 0.5 Abs/m
+/- 2%
COD by UV correlation0-100 mg/l COD
0-2000 mg/l COD
0-20,000 mg/l COD
+/-0.05 mg/l COD
+/- 1 mg/l COD
+/- 10 mg/l COD
+/- 2%
BOD by UV correlation0-100 mg/l BOD
0-1000 mg/l BOD
0-10,000 mg/l BOD
+/-0.05 mg/l BOD
+/- 0.5 mg/l BOD
+/- 5 mg/l BOD
+/- 2%
TOC by UV correlation0-100 mg/l TOC
0-1000 mg/l TOC
0-10,000 mg/l TOC
+/-0.05 mg/l TOC
+/- 0.5 mg/l TOC
+/- 5 mg/l TOC
+/- 2%
Ammonia0-100 mg/l NH4+/- 0.2 mg/l NH4+/- 5%
Nitrate (NO3)0-100 mg/l NO3+/- 0.1 mg/l NO3+/- 2%
Colour0-100 Pt/Co
0-1000 Pt/Co
+/- 0.2 Pt/Co
+/- 2 Pt/Co
+/- 2%
PAH (aromatics)0-10 mg/l C6H6+/- 0.01 mg/l C6H6+/- 2%
Oil in Water0-100 ppm OIW
0-1000 ppm OIW
+/- 0.1 ppm OIW
+/- 1 ppm OIW
+/- 2%
Phosphate0-2 mg/l P-PO4
0-20 mg/l P-PO4
+/- 0.01 mg/l P-PO4
+/- 0.1 mg/l P-PO4
+/- 2%
Hydrogen Sulphide0-20 mg/l H2S+/-1 mg/l H2S+/- 2%
Chromium IV0-2 mg/l Cr VI+/-0.04 mg/l Cr VI+/- 2%
Turbidity
(TSS by correlation)
0-10 NTU
0-100 NTU
0-1000 NTU
+/- 0.01 NTU
+/- 0.1 NTU
+/- 1 NTU
+/- 2%
pH0-14 pH+/- 0.01 pH+/- 2%
ORP+/- 2000 mV+/- 1 mV+/- 2%
Dissolved Oxygen(DO)0-25 mg/l O2+/- 0.1 mg/l O2+/- 2%
Conductivity0-2000 μS+/- 1 μS+/- 2%
External turbidity
(TSS by correlation)
0-4 NTU
0-40 NTU
0-400 NTU
 +/- 2%
+/- 2%
+/- 2%
External TSS0-1500 mg/l TSS
0-30000 mg/l TSS
+/- 1% of reading or +/- 2 mg/l TSS
+/- 1% of reading or +/- 2 mg/l TSS
 
Temperature0-80°C+/- 0.1 °C+/- 2%

 

Online water analyzer, UV500 - General specification

Sample flowRecommended : 0 - 5 L/MIN
0 – 0.5 l/min for NH4 or H2S
Sample pressure0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump)
0 – 0.5 Bar for NH4 or H2S
Sample temperature0 °C to 80 °C
0°C to 30°C for NH4 or H2S
Wet parts materialQuartz, Polypropylene, Polyethylene, FPM (Viton), PMMA (+ Pharmed and glass for NH4 or H2S)
Measurement interval1 min to 720 min
Physicochemical parameters may be continuous
Memory5000 lines of measurements (up to 16 channels) with date and time
ConsumptionCleaning solution (5% sulfuric acid): 220 ml/day
Reagent for PO4: 2 ml per measurement
NaOH 10% for NH4: 2 ml per measurement
HCl 10% for H2S: 2 ml per measurement
Maintenance intervalRecommended: 6 months to 1 year (except for refilling)
Power supply90 - 264 VAC 50/60 Hz 80 VA
ScreenColour TFT LCD 640x480 pixels with LED backlight
CommunicationRS232 with MODBUS protocol
RS485 for external probes (DO, TSS)

USB
WI-FI (IEEE802.11B) optional
Ethernet (IEEE802.3) optional
CertificationsCE, EN 61010-1, EN 61326e
EnclosureStainless steel with epoxy coating, IP65, wall mounting brackets
Dimensions525x345x260 mm
Weight20 to 30 kg depending on the configuration

 

UV500 Parts references

Basic Unit 
Sampling pump 
pectrograph (required for UV254, COD, BOD, TOC, NO₃, Colour, PO₄, Cr VI, NH₄ and H₂S measurements) 
Absorbance flow cell and xenon lamp (required for UV254, COD, BOD, TOC, NO₃, Colour, PO₄, Cr VI measurements) 
Configuration and calibration for measurements by absorbance (require SPECTRO500 and ABS500 modules) 
Measurement by UV fluorescence (required for PAH and OIW measurements) 
Measurement module by colorimetric method (require SPECTRO500 and ABS500 module) 
Measurement by nephelometry 
Measurements by optical method 
Measurement by UV absorption in gas phase 
Input modules 
Measurements by electrode (external) 
Output modules 
Recommanded consumables for 2 years : 
UV500Basic unit (no measurement included
Color graphic display 640x320 pixels with touch screen
Built-in data logger, memory 5000 measurements for each parameter 12 sockets for input and output modules (not included, refer to options) 7 available glands for inputs / outputs
RS232 included (Sub-D 9 ways female connector) with 2 meters cable for PC RS485 included for communication with MODBUS protocol
USB port included for USB key connection Automatic cleaning system with 2 liters tank
Power supply 90 - 264 VAC / maxi 100 VA : 50 - 60 Hz with power cord 2 meters Enclosure IP65/Nema4x stainless steel 316 521x473x250 mm (HxWxD) / 20 to 30 kg Mounting lugs for wall
UV500-P (Premium)Basic unit (no measurement included
Same specifications as UV500 except dimensions : 525x473x260 mm
PSampling peristaltic pump for unpressurized water
Flow of about 940 mL/min Heavy duty brushless motor
Discontinuous operating to increase tube lifetime
P-EXTExternal Peristaltic sampling pump for unpressurized water
Built-in on the left side of the enclosure Flow of about 600 mL/min
Discontinuous operating to increase tube lifetime
SPECTRO500UV-Visible spectrograph
Range: 180 – 750 nm
Resolution 0.29 nm
2048 pixels
ABS500Flow cell and xenon lamp for absorbance measurements
Optical path: 1, 3 or 10 mm Lamp life time: 109 flashes
Wet materials: PMMA, Viton, Quartz
COD-H-500high range: 0 – 2000 Abs/m
(equivalent to approx. 20000 mg/L COD on municipal waste water)
COD-M-500Organic matter Medium range medium range: 0 – 600 Abs/m (equivalent to 2000 mg/L COD)
COD-L-500Organic matter low range
low range: 0 – 200 Abs/m
(equivalent to 100 mg/L COD on river water)
NO3-500Nitrate
Range: 0 – 100 mg/L NO₃ (0 – 25 mg/L N of NO₃) Measurement possible until 250 mg/L NO₃ (60 mg/L N-NO₃)
CO-H-500Colour high range
Range: 0 – 1000 Pt-Co unit
CO-L-500Colour low range
Range: 0 – 100 Pt-Co unit
PAH-500Poly-aromatic hydrocarbons
Range: 0 – 10 ppm phenol
Range: 0 – 100 ppm OIW
(equivalent to approx. 0 – 100 ppm oil with 10% aromatic ratio)
PO4-H-500Phosphate high range
High range: 0 – 20 mg/L P (60 mg/L PO₄) Sampling peristaltic pump included
CR6-500Hexavalent chromium (VI)
Range: 0 – 2 mg/L Cr VI
Measurement possible up to 5 mg/L Cr VI
PO4-L-500Phosphate low range
Low range: 0 – 2 mg/L P (6 mg/L PO₄) Sampling peristaltic pump included
IRTURB-H-500Internal turbidity sensor high range
High range: 0 – 1000 NTU
Nephelometric method by laser diode at 650 nm (850 nm on request)
IRTURB-M-500Internal turbidity sensor medium range
Low range: 0 – 100 NTU
Nephelometric method by laser diode at 650 nm (850 nm on request)
IRTURB-L-500Internal turbidity sensor low range
Low range: 0 – 10 NTU
Nephelometric method by laser diode at 650 nm (850 nm on request)
DO-FDissolved oxygen probe by fluorescence
Range: 0 - 25 mg/L O₂ 7 meters of cable
EXT-TURB-HTurbidity probes high range High range: 0 – 30000 mg/L TSS 7 meters cable
EXT-TURB-LTurbidity probes low range Low range: 0 – 1500 mg/L TSS 7 meters cable
EXT-TURBNEPH-HNephelometric turbidity probes high range
Range: 0 – 400 NTU
10 meters cable
EXT-TURBNEPH-MNephelometric turbidity probes medium range
Range: 0 – 40 NTU
10 meters cable
EXT-TURBNEPH-LNephelometric turbidity probes low range
Range: 0 – 4 NTU
10 meters cable
STRIP500Stripping system
Include xenon lamp, flow cell, glassware, air pump, air filter and solenoid valve
NH4-500Ammonia
Range: 0 – 100 ppm NH₄+
H2S-500Hydrogen sulfide
Range: 0 – 20 ppm H₂S
IN4-20-5004-20 mA input module Isolated 4-20 mA input Impedance: 100 Ohm
LOGIC500Double logical inputs module
Input no 1 : external pulse command for measurement
Input no 2 : measurements inhibition Isolated 0 – 48 V DC inputs Impedance: >10 Kohm
PH500pH/ORP module
pH Range: 0 – 14
ATC input for platinum RTD 100 Ohm or 1000 Ohm
ORP Range: -2000 mV to +2000 Mv
COND500Conductivity module
Range: 0 – 100 µS/cm to 0 – 100 mS/cm ATC input for platinum RTD 100 Ohm
ELPHpH on-line electrode
Range: 0 – 14
5 meters of cable (10 meters in option) Built-in ATC RTD 100 Ohm
ELORPORP on-line electrode
Range: -2000 mV to +2000 Mv
5 meters of cable (10 meters in option) Built-in ATC RTD 100 Ohm
ELCONDConductivity on-line electrode
Range: 0 – 10 mS/cm
Cell constant k=1.0 cm-1 (medium range) 5 meters of cable (10 meters in option) Built-in ATC RTD 100 Ohm
ICONDInductive conductivity online probe
Range: 0 – 100 mS/cm 3 meters of cable
Built-in temperature compensation at 2.2%/°C Requires a IN4-20-500 module instead of COND500 module
OUT4-20-500OUT4-20-500
Isolated 4-20 mA output
Active output, Max load 500 Ohm
RELAY500RELAY500
RELAY500
P-ACI-HD1 :Head of cleaning pump (x1)
P-RGT-HD1 :Head of reagent pump (x1) (only for NH₄ or H₂S)
T-PHAR-1 :Tubing 6.4x9.6 mm (if optional sampling pump) (x2 to x8 depending on sampling pump use)
Cleaning solution and reagents (if any) are not provided 

 

Online water analyzer, UV500 - Accessories

Sampling pump
Product code: P

Sampling peristaltic pump for unpressurized water
Built-in on the left side of the enclosure
Flow of about 0.6 litre/min
Discontinuous operating to increase tube lifetime
 

Sampling pump
Product code: P-EXT

External Peristaltic sampling pump for unpressurized water
Flow of about 940 ml/min
Heavy duty brushless motor
Discontinuous operating to increase tube lifetime
 

Input modules
Product code: IN4-20-500

4-20 mA input module
Isolated 4-20 mA input
Impedance: 100 Ohm
 

Input modules
Product code: LOGIC500

Double logical inputs module
Input no 1 : external pulse command for measurement
Input no 2 : measurements inhibition
Isolated 0 – 48 V DC inputs
Impedance: >10 Kohm
 

Output modules
Product code: OUT4-20-500

4-20 mA output module
Isolated 4-20 mA output
Active output, Max load 500 Ohm
 

Output modules
Product code: RELAY500

Relay module
Contact rating: 2A/220V
 

Communications
Product code: WIFI500

Wifi Interface
Connection to wireless WIFI network
Secured data transfer (WEP keys)
 

Communications
Product code: ETHER500

Ethernet interface
Ethernet 10 base-T (IEEE 802.3)
Secured data transfer (WEP keys)
 

Communications
Product code: MTI133

Phone modem
Industrial modem 33,6 Kb/s V34+
DIN rail Mounting
Power supply 24V from the analyser
 

Communications
Product code: GSM

GSM modem
Dual band (EGSM 900/1800 MHz)
Integral SIM card reader
R & TTE approved

Related Products

OPSA-150

OPSA-150

Long-term stable and high-precision measurements are achieved through our unique rotary cell length modulation method.

UV500

UV500

Online UV‑Visible Water Analyzer

UV300

UV300

Online Water Analyzer

HT-110

HT-110

On-line TOC analyzer

HU-200TB-IM

HU-200TB-IM

Immersion-Type Turbidity & Suspended Solids Analyzer

HC-200NH

HC-200NH

Field-Installation Ammonia Nitrogen Analyzer

NOT SURE WHAT YOU ARE LOOKING FOR?

BOOK A CONSULTATION

Our experts are here to guide you to the right solution. Fill out the form and we'll get in touch shortly.

*
*
*
*
*