VA-5000-Siloxane
Total Siloxane Analyzer
The VA-5000 Total Siloxane Analyzer delivers high-sensitivity, continuous monitoring of siloxane in gas streams, with optional simultaneous measurement of methane (CH₄) and carbon dioxide (CO₂). Customizable to the type of cyclic siloxane being tested, this analyzer is ideal for durability testing, biogas fuel quality control, and preventing siloxane-related wear in gas engines.
Why Choose VA-5000-Siloxane
Sensitive, Real-Time Siloxane Detection – Measures siloxane concentrations continuously with high accuracy.
-
Optional Multi-Gas Capability – Can concurrently monitor CO₂ and CH₄ for comprehensive fuel assessment.
-
Supports Durability Testing – Useful in relays, motors, and contact parts to prevent siloxane-induced failures.
-
Protects Biogas Engines – Prevents damage by tracking siloxane levels in biogas before combustion.

Key Advantages of VA-5000-Siloxane
Highly Sensitive Siloxane Monitoring
Delivers accurate, continuous detection of siloxane down to very low levels.
Simultaneous Gas Measurement
Enables full fuel quality profiling with combined monitoring capability.
Prevents Equipment Failures
Helps avoid siloxane buildup and contact failures in motors and gas engines.
Plug-and-Play Sampling
Compact Panel-Mount Design
Technical Specifications of VA-5000-Siloxane
Components | Siloxane | CO2 | CH4 |
Measurement principle | NDIR: Non-Dispersive Infrared | ||
Measurement range | 0-50 ppm (single range) | 0-50 vol% (single range) | 0-100 vol% (single range) |
Repeatability | ±1% full scale | ±2% full scale | |
Linearity | ±2% full scale | ||
Zero drift | ±2% full scale per day | ||
Span drift | ±2% full scale per day | ||
Sample gas flow rate | Approx. 0.5 L/min | ||
Display | 5.7-inch touch screen | ||
Output | DC 4-20 mA (non-insulated) / DC 0-1 V(non-insulated) | ||
Installation environment | Ambient temperature: 0℃ to 40℃, Relative humidity: 90% or less | ||
Power supply | 100-240V AC (±10%, maximum voltage 250V AC), 50 Hz/60 Hz | ||
Power consumption | 100 to 350 VA | ||
Dimensions | 430(W) X 380(D) X 132(H) mm | ||
Case | 19-inch panel mount | ||
Weight | Approx. 7-18 kg | ||
Sample gas conditions | Temperature: Ambient temperature, Dust: None, Moisture: Less than 5℃ saturation Pressure: 490 Pa or less, Other: No corrosive gases *For the measurement of siloxane in biogas Gas composition: CO2 10 to 50 vol%/CH4 base (However, CO2 concentration fluctuation range should be within 20%) *Please consult HORIBA in case of not meeting the above conditions. |
*Please consult HORIBA about the type of siloxane to be measured.
*Analyzer can be accommodated with additional galvanic cell type O2 analyzer and provide measurement of up to 4 components. Please contact us for details.
Preprocessing Cooler Unit PS-300S
Model | PS-300S | ||
Materials in contact with sample gas | Ti, SUS, PVC, PTFE, FKM, PVDF, PP, Glass | ||
Sample gas flow rate | Max. 0.5 L/min | ||
Sample gas discharge | Max. 0.5 L/min | ||
Dehumidifying capacity | 5℃ saturated | ||
Installation environment | Ambient temperature: 0℃ to 40℃, Ambient humidity: 85% or less | ||
Power supply | 100 V AC, 50 Hz/60 Hz *Please consult HORIBA if other power supply is required | ||
Dimensions | 260 (W) × 375 (D) × 235 (H) mm (except for protrusion) | ||
Mass | Approx. 12 kg | ||
Sample gas condition | Temperature: Ambient temperature, Dust: None, Moisture: Ambient temperature below saturation (no condensation) Pressure: Atmospheric pressure ±5 kPa |