VA-5000-Siloxane

VA-5000-Siloxane

Total Siloxane Analyzer

The VA-5000 Total Siloxane Analyzer delivers high-sensitivity, continuous monitoring of siloxane in gas streams, with optional simultaneous measurement of methane (CH₄) and carbon dioxide (CO₂). Customizable to the type of cyclic siloxane being tested, this analyzer is ideal for durability testing, biogas fuel quality control, and preventing siloxane-related wear in gas engines.

Why Choose VA-5000-Siloxane

  • Sensitive, Real-Time Siloxane Detection – Measures siloxane concentrations continuously with high accuracy.

  • Optional Multi-Gas Capability – Can concurrently monitor CO₂ and CH₄ for comprehensive fuel assessment.

  • Supports Durability Testing – Useful in relays, motors, and contact parts to prevent siloxane-induced failures.

  • Protects Biogas Engines – Prevents damage by tracking siloxane levels in biogas before combustion.

Why Choose

Key Advantages of VA-5000-Siloxane

Highly Sensitive Siloxane Monitoring

Real-Time Precision

Delivers accurate, continuous detection of siloxane down to very low levels.

Simultaneous Gas Measurement

CO₂ & CH₄ Optional

Enables full fuel quality profiling with combined monitoring capability.

Prevents Equipment Failures

Engine & Relay Protection

Helps avoid siloxane buildup and contact failures in motors and gas engines.

Plug-and-Play Sampling

Compact Panel-Mount Design

Compact Panel-Mount Design

Technical Specifications of VA-5000-Siloxane

Components Siloxane CO2 CH4 
Measurement principleNDIR: Non-Dispersive Infrared
Measurement range0-50 ppm (single range)0-50 vol% (single range)0-100 vol% (single range)
Repeatability   ±1% full scale  ±2% full scale
Linearity   ±2% full scale
Zero drift  ±2% full scale per day
Span drift  ±2% full scale per day
Sample gas flow rate   Approx. 0.5 L/min
Display   5.7-inch touch screen
Output   DC 4-20 mA (non-insulated) / DC 0-1 V(non-insulated) 
Installation environment Ambient temperature: 0℃ to 40℃, Relative humidity: 90% or less
Power supply100-240V AC (±10%, maximum voltage 250V AC), 50 Hz/60 Hz 
Power consumption100 to 350 VA
Dimensions   430(W) X 380(D) X 132(H) mm
Case 19-inch panel mount
Weight  Approx. 7-18 kg

Sample gas conditions
 Temperature: Ambient temperature, Dust: None, Moisture: Less than 5℃ saturation
 Pressure: 490 Pa or less, Other: No corrosive gases
 
*For the measurement of siloxane in biogas
  Gas composition: CO2 10 to 50 vol%/CH4 base (However, CO2 concentration fluctuation range should be within 20%)
*Please consult HORIBA in case of  not meeting the above conditions. 
scrollable

*Please consult HORIBA about the type of siloxane to be measured.
*Analyzer can be accommodated with additional galvanic cell type O2 analyzer and provide measurement of up to 4 components. Please contact us for details.

 

Preprocessing Cooler Unit PS-300S

Model PS-300S
Materials in contact with sample gas Ti, SUS, PVC, PTFE, FKM, PVDF, PP, Glass
Sample gas flow rate Max. 0.5 L/min
Sample gas discharge Max. 0.5 L/min
Dehumidifying capacity 5℃ saturated
Installation environment  Ambient temperature: 0℃ to 40℃, Ambient humidity: 85% or less
Power supply 100 V AC, 50 Hz/60 Hz
 *Please consult HORIBA if other power supply is required
Dimensions 260 (W) × 375 (D) × 235 (H) mm (except for protrusion)
Mass Approx. 12 kg
Sample gas condition Temperature: Ambient temperature, Dust: None,
 Moisture: Ambient temperature below saturation (no condensation)
 Pressure: Atmospheric pressure ±5 kPa

Related Products

IT-270

IT-270

High-Accuracy Infrared Thermometer

ENDA-5000 Series

ENDA-5000 Series

Stack Gas Analysis System

APMA-370

APMA-370

Ambient Carbon Monoxide Analyzer

APOA-370

APOA-370

Ambient Ozone Monitor

GA-370

GA-370

Trace Gas Monitor

PLGA-1000

PLGA-1000

Process Laser Gas Analyzer

NOT SURE WHAT YOU ARE LOOKING FOR?

BOOK A CONSULTATION

Our experts are here to guide you to the right solution. Fill out the form and we'll get in touch shortly.

*
*
*
*
*