APMA-370
Ambient Carbon Monoxide Analyzer
The APMA-370 continuously monitors CO concentrations in ambient air using cross‑flow non‑dispersive infrared (NDIR) absorption with an internal dry‑method sampling device, delivering high sensitivity and accuracy with minimal maintenance.
Why Choose APMA-370
- Cross‑flow NDIR detector for stable CO measurement
- AS‑type interference‑compensating detector and reference gas purifier
- Reference gas purifier oxidizes CO to CO₂ to eliminate interferences
- Internal dry‑method sampling device for high sensitivity
- Mirror‑free optics prevent contamination
- Robust design for continuous ambient operation

Key Advantages of APMA-370
High precision
Maintains accuracy across full‑scale ranges
Flexible range selection
standard
4 optional ranges up to 0–200 ppm
manual switching
Robust interference compensation
Eliminates cross‑gas and shock‑induced errors
Applications of APMA-370
Urban air quality monitoring
Continuous CO profiling in environmental stations
Industrial perimeter emission control
Detects factory CO leaks
Tunnel ventilation management
Real‑time CO data for airflow optimization
Roadside air pollution surveillance
Monitors vehicular CO impact
Indoor workplace safety
Tracks CO in confined occupational settings
Environmental impact assessment
Baseline CO levels for regulatory compliance
Technical Specifications of APMA-370
Principle | Cross flow modulation, non-dispersive infrared (NDIR) absorption technology |
Application | CO in ambient air |
Range | Standard ranges: 0-10/20/50/100 ppm; 0-5/10/20/50 ppm; auto range ~ manual range selectable; can be operated by remote switching. Optional (measurable) ranges: 4 ranges selectable from 0-200 ppm, within 10 times range ratio; auto range ~ manual range selectable; can be operated by remote switching. |
Repeatability | ±1.0% of F.S. |
Linearity | ±1.0% of F.S. |
Sample gas flow rate | Approx. 1.5L/min |
Indication | Measured value, range, alarm, maintenance screen |
Alarms | During AIC, zero calibration error, span calibration error, temperature error in catalyzer, etc. |
On-screen messages are available in four languages | English, German, French, and Japanese |
Input/output | • 0-1 V/0-10 V/4-20 mA, to be specified (2 systems: either (1) momentary value and integrated or (2) moving average value) • Contact input/output • RS-232C |
Power | 100/110/115/120/220/230/240 VAC, 50/60 Hz (to be specified) |
Dimensions | 430(W) x 550(D) x 221(H) mm |
Mass | Approx. 16 kg |
** Certified to U.S. EPA Reference Method RFCA