APHA-370
Hydrocarbon Monitor / THC Analyser
The APHA-370 offers continuous, high-precision monitoring of total hydrocarbons (THC), methane (CH₄), and non-methane hydrocarbons (NMHC) in ambient air. Using a flame ionization detector with cross-flow modulation technology, it delivers stable, interference-free readings with minimal maintenance.

Why Choose APHA-370
Multi-Gas Detection – Simultaneously measures THC, CH₄, and NMHC for comprehensive air analysis.
-
Stable, Drift-Free Performance – Single-detector cross-flow modulation maintains calibration with high baseline stability.
-
Low-Maintenance Design – Built-in sample pump and reference air system enable long-term operation with minimal servicing.
-
Environmental & Industry Ready – Ideal for ambient monitoring, clean-room contamination tracking, and methane purity checks.

Key Advantages of APHA-370
1.
Comprehensive Gas Monitoring
Delivers simultaneous measurement for complete hydrocarbon profiling.
2.
Reliable & Stable Output
Cross-flow modulation ensures long-term baseline accuracy without frequent re-calibration.
3.
Continuous Low-Maintenance Use
Includes internal pump and reference air system for uninterrupted monitoring.
4.
Ideal for Sensitive Environments
Perfect for environmental studies and contamination control in semiconductor fabrication.
Technical Specifications of APHA-370
Measuring principle | Flame ionization detector(FID) | |
Applications | THC Measurement in ambient air | |
Measuring range | • standard : 0-5/ 10/ 25/ 50 ppm Can be controlled manually, automatically or externally • max. measuring range ratio = 1:10 | |
Limit of detection | 0,022 ppm (3δ) | |
Repeatability | ±1.0 % of full scale | |
Linearity | ±1.0 % of full scale | |
flow rate | ca. 0,5 l/min | |
Response time (T90) | < 60 sec. (lowest range) | |
Display | Concentration in ppm (ppb) or mg (µg)/m3 | |
Compensation | pressure and temperatur | |
Languages | German, English, French, Japanese | |
Interfaces | RS-232C (Gesytec / HORIBA Protocol) | |
Options | • Ethernet Interface • Analooutput 0-1/10 V or 0(4) - 20 mA • Long-term data storage • Calibration units • Further options on request | |
Ambient temperature | 0-40°C | |
Power supply | 240 VAC, 50 Hz, ca. 170 VA | |
Dimensions | 430(W) x 550(D) x 221(H) mm (5HE) | |
weight | Approx. 33 Kg. |