APDA-371

APDA-371

Ambient Dust Monitor

The APDA-371 is a robust ambient dust (particulate matter) monitor that uses the proven principle of beta-ray attenuation on a tape filter. It provides accurate, automatic hourly measurements of PM levels—compliant with regulatory standards and engineered for reliable long-term outdoor deployment.

Why Choose APDA-371

  • Highly Accurate PM Detection – Uses beta-ray attenuation for precise measurement of particulate concentrations.

  • Low-Maintenance Design – Operates continuously for weeks without needing operator intervention.

  • Built-In Self-Diagnostics – Performs automatic zero/span checks and drift monitoring to ensure ongoing calibration.

  • Convenient Data Interface – Stores digital data on-board with flexible output for easy retrieval and analysis.

Why Choose

Key Advantages of APDA-371

Regulatory-Level Precision

Beta-Ray Attenuation

Provides accurate quantification of PM, aligning with PM2.5 and PM10 standards.

Long Unattended Operation

Weeks of Runtime

Operates continuously with minimal maintenance requirements.

Automatic Calibration Checks

Automatic Calibration Checks

Automatic Calibration Checks

Flexible Data Connectivity

Internal Memory + Output

Supports data access via LAN, RS-232, analog outputs, or external devices.

Technical Specifications of APDA-371

Measurement Principle

Particulate Concentration by Beta Ray Attenuation

Application

PM10 or PM2,5 or TSP Measurement

Range

0-1,000mg/m3(standard), 0-1.000µg/m3

0-100, 200, 250, 500, 2000, 5000, 10.000µg/m3(special application)

Lowest Detection Limit (1h)

< 4,8µg/m3 

Lowest Detection Limit (24h)

< 1,0µg/m3

Measurement cycle time

1 hour

Flow Rate

16,70 liters/minute

Filter Tape

Glass fiber filter

Span Check

Nominally 800µg/cm2

Beta Source

C-14 (carbon-14), 60 μCi ±15 μCi (< 2.22 X 106 Beq), Half-Life 5730 years.

Beta Detector Type

Photomultiplier tube with scintillator

Operation Temperature

0° to +50°C

Ambient Temperature   

-40° to +55°C standard. Optional -50 °C temperature sensors available

Ambient Humidity

0 to 90% RH, non-condensing

Data Interface  

RS-232, LAN connecting terminal(TCP/IP), Analog (0-10V, 4-20mA, 0-16mA)

Power

AC100 - 230 VAC± 10V, 50/60 Hz, approx. 0,4kW

Dimensions

310(H) x 430(W) x 400(D) mm

Mass

24.5 kg without Accessories

Related Products

IT-270

IT-270

High-Accuracy Infrared Thermometer

ENDA-5000 Series

ENDA-5000 Series

Stack Gas Analysis System

APMA-370

APMA-370

Ambient Carbon Monoxide Analyzer

APOA-370

APOA-370

Ambient Ozone Monitor

GA-370

GA-370

Trace Gas Monitor

PLGA-1000

PLGA-1000

Process Laser Gas Analyzer

NOT SURE WHAT YOU ARE LOOKING FOR?

BOOK A CONSULTATION

Our experts are here to guide you to the right solution. Fill out the form and we'll get in touch shortly.

*
*
*
*
*