PLGA-1000
Process Laser Gas Analyzer
The PLGA-1000 Process Laser Gas Analyzer is designed to measure hydrocarbons and other gases contained in process gases at petrochemical plants. It uses proprietary IRLAM™ technology to continuously measure low concentrations of acetylene (C2H2) and carbon dioxide (CO2) as impurities in high‑concentration methane (CH4) and ethane (C2H6), delivering high‑speed, high‑sensitivity performance.
Why Choose PLGA-1000
- Probe‑type optical system for in‑situ HCl measurement
- Both laser and receiver on same‑side probe for compact operation
- Single‑flange installation reduces setup complexity
- Easy swap‑in replacement with existing analyzers
- Stabilized optical axis ensures measurement precision
- Continuous moisture correction maintains accuracy in humid gases

Key Advantages of PLGA-1000
Simplified installation
Minimizes installation complexity in tight stacks
Robust measurement stability
Ensures repeatable HCl readings over long‑term operation
Precise moisture compensation
Maintains accuracy in high‑humidity flue gases
Compact probe design
Saves space and simplifies maintenance access
Technical Specifications of PLGA-1000
Name | Process Laser Gas Analyzer |
Model | PLGA-1000 |
Measurement principle | NDIR: Non Dispersive Infrared |
Light source | QCL: Quantum Cascade Laser |
Laser class | Class 1(IEC 60825-1:2014) |
[ For C2H2 Converter Inlet ]
Components*¹ | Acetylene (C2H2), Carbon monoxide (CO) |
Range | C2H2 : 0 - 10000 ppm, CO: 0 - 2000 ppm |
Linearity | ±1.0 % full scale |
Response time | Td + T90 : 3 seconds at 1.6L / min |
Zero drift | ±2.0 % full scale per 1 month |
Span drift | ±2.0 % full scale per 1 month |
[ For C2H2 Converter Outlet ]
Components*¹ | Acetylene (C2H2), Carbon monoxide (CO) |
Range | C2H2 : 0 - 10 ppm, CO: 0 - 10 ppm |
Linearity | ±1.0 % full scale |
Response time | Td + T90 : 7seconds at 1.6L / min |
Zero drift | ±3 % full scale per 1 month |
Span drift | ±3 % full scale per 1 month |
[ For C2 Splitter Inlet ]
Components*¹ | Methane (CH4), Ethane (C2H6), Acetylene (C2H2), Carbon Dioxide (CO2) |
Range | CH4 : 0 - 2000 ppm or 0 - 5 vol% C2H6 : 0 - 50 vol% C2H2 : 0 - 50 ppm CO2 : 0 - 200 ppm |
Linearity | ±1.0 % full scale |
Response time | Td + T90 : 3 sec at 1.6L / min |
Zero drift | ±2.0 % full scale per 1 month |
Span drift | ±2.0 % full scale per 1 month |
[ Common ]
Repeatability | ±1.0 % full scale |
Data update cycle | 1 sec |
Calibration interval | 1 month |
Ambient temperature | -10˚C to 50˚C or -10˚C to 45˚C (no direct sun rays, including case temperature influences due to radiant heat and heat conduction) *The flow rate of the protective gas differs depending on the specification of the ambient temperature |
Hazardous area classification | US, Canada: Class I, Division 2, Groups A, B, C, D T4 US: Class I, Zone 2, AEx pzc IIC T4 Gc IECEx, Canada: Ex pzc IIC T4 Gc ATEX, UKCA: ![]() |
Protection class | IP66、NEMA4X |
Wetted materials | SS316, SS304, BaF2, FKM, PTFE, Au, Ni |
Gas connector size | 1/4"NPT, 1/2"NPT (Option: N2 generator) |
Pressure error alarm output | Three channels (Main enclosure, Optical unit, Cell) DC 5 V to 24 V, 1 A at each terminal |
Communication function | Modbus®/ TCP |
Analog output | Four channels (Gas concentration) 4 mA to 20 mA Max. load: 550 Ω |
Contact output | Three channels (Calibration / Main alarm / Measurement) Relay contact output (isolated output) DC 5 V to 24 V, 1 A at each terminal |
Digital output | One channel (For signal barrier power control relay) DC 24 V, 100 mA |
Dimension | 664 mm (W) x 270 mm (D) x 704 mm (H) *Protrusions included |
Weight | Standard 46 kg, Max. 50 kg *Depends on product specifications |
Power supply | AC 100 V to 120 V, 50 Hz/60 Hz or AC 200 V to 240 V, 50 Hz/60 Hz |
Power consumption | Max. 250 VA |
*¹ Please contact us for other components and range.
Modbus is a trademark of Schneider Electric USA Inc.