GA-370

GA-370

Trace Gas Monitor

GA-370 provides constant, ultrahigh-sensitivity and high-precision monitoring of trace impurities (CO, CO₂ and CH₄) for quality control at gas manufacturing and separation facilities.

Why Choose GA-370

  1.  Cross‑flow modulation dual‑beam NDIR for zero‑drift stability
  2.  10 ppb MDL enabling ultrahigh sensitivity
  3.  Measures CO, CO₂ & CH₄ in balance gases (N₂, O₂, He, Ar, H₂, Air)
  4.  No optical alignment required, touch‑color LCD simplifies operation
  5.  Continuous 24/7 monitoring with low maintenance.
Why Choose

Key Advantages of GA-370

High Sensitivity

MDL: 10 ppb 

Detects trace impurities for ultra‑pure gas QC

Wide Gas Compatibility 

N₂, O₂, He, Ar, H₂ & Air

Versatile for various balance gases

Stable Zero Drift 

Cross‑flow NDIR dual‑beam

Ensures long‑term reliability

User‑Friendly Interface 

Touch‑color LCD & intuitive menus

Simplifies operation and data review.

Applications of GA-370

Air Separation Plant PPU Monitoring

Continuous CO, CO₂ & CH₄ tracking to prevent distillation unit plugging

Semiconductor Gas Purity Assurance

Quality control of N₂ & O₂ in fab supply

Medical Gas Cylinder QC

Ensures trace impurity compliance in O₂ & N₂ cylinders

Hydrogen Fuel Cell Check

On‑site H₂ impurity measurement for FCV fueling stations

Reference Gas Generation Labs

Low‑level gas calibration and testing

Coal & Fuel Trace Gas Monitoring

Detects CO₂ & CH₄ in fuel reactivity studies

Technical Specifications of GA-370

Model GA-370
Gases measured CO, CO2, CH4
Bulk gases N2, O2, He, Ar, H2, Air
Number of measurement components 1 component or 2 components (specify a measuring balance gas)
Measuring principle Cross-flow modulation non-dispersive infrared (NDIR) absorption method
Measurement ranges 0 to 1/2/5/10 ppm
Lowest detection limit (2σ) 10 ppb
Repeatability ≤ ± 2% of full scale
Indication error ≤ ± 2% of full scale
Zero Drift ≤ ± 0.02 ppm/day, ≤ ± 0.03 ppm/week
Span Drift ≤ ± 2% of full scale/day, ≤ ± 2% of full scale/week
Response time (T90) ≤ 180s
Gas flow rate 

Sample gas : approx. 3.5L/min, reference gas : approx. 3.5L/min, span gas: approx. 3.5L/min

Note: A delivery pressure of 50-100kPa is recommended for both sample and reference gas.

Analog output 

Max. 2 channels isolated output (2 components)

Select one from 0 to 1V, 0 to 10V, 0 to 16mA, 4 to 20mA or 0 to 20mA.

Current output : Allowable load resistance 750Ω or less

Installation conditionsAmbient temperature0 to 40°C
Ambient relative humidity≤85%
DustLess than environmental standard
Vibration≤ 0.29m/s², at ≤ 100Hz
External dimensions, weight 430(W) x 221(H) x 555(D) mm (excluding protrusions), approx. 18kg
Power supply 100 to 240V AC, ≤ ± 10% (max. voltage: 250V AC)
Power consumption Approx. 100VA

Related Products

IT-270

IT-270

High-Accuracy Infrared Thermometer

ENDA-5000 Series

ENDA-5000 Series

Stack Gas Analysis System

APMA-370

APMA-370

Ambient Carbon Monoxide Analyzer

APOA-370

APOA-370

Ambient Ozone Monitor

GA-370

GA-370

Trace Gas Monitor

PLGA-1000

PLGA-1000

Process Laser Gas Analyzer

NOT SURE WHAT YOU ARE LOOKING FOR?

BOOK A CONSULTATION

Our experts are here to guide you to the right solution. Fill out the form and we'll get in touch shortly.

*
*
*
*
*