GA-370
Trace Gas Monitor
GA-370 provides constant, ultrahigh-sensitivity and high-precision monitoring of trace impurities (CO, CO₂ and CH₄) for quality control at gas manufacturing and separation facilities.
Why Choose GA-370
- Cross‑flow modulation dual‑beam NDIR for zero‑drift stability
- 10 ppb MDL enabling ultrahigh sensitivity
- Measures CO, CO₂ & CH₄ in balance gases (N₂, O₂, He, Ar, H₂, Air)
- No optical alignment required, touch‑color LCD simplifies operation
- Continuous 24/7 monitoring with low maintenance.

Key Advantages of GA-370
High Sensitivity
Detects trace impurities for ultra‑pure gas QC
Wide Gas Compatibility
Versatile for various balance gases
Stable Zero Drift
Ensures long‑term reliability
User‑Friendly Interface
Simplifies operation and data review.
Applications of GA-370
Air Separation Plant PPU Monitoring
Continuous CO, CO₂ & CH₄ tracking to prevent distillation unit plugging
Semiconductor Gas Purity Assurance
Quality control of N₂ & O₂ in fab supply
Medical Gas Cylinder QC
Ensures trace impurity compliance in O₂ & N₂ cylinders
Hydrogen Fuel Cell Check
On‑site H₂ impurity measurement for FCV fueling stations
Reference Gas Generation Labs
Low‑level gas calibration and testing
Coal & Fuel Trace Gas Monitoring
Detects CO₂ & CH₄ in fuel reactivity studies
Technical Specifications of GA-370
Model | GA-370 | |
Gases measured | CO, CO2, CH4 | |
Bulk gases | N2, O2, He, Ar, H2, Air | |
Number of measurement components | 1 component or 2 components (specify a measuring balance gas) | |
Measuring principle | Cross-flow modulation non-dispersive infrared (NDIR) absorption method | |
Measurement ranges | 0 to 1/2/5/10 ppm | |
Lowest detection limit (2σ) | 10 ppb | |
Repeatability | ≤ ± 2% of full scale | |
Indication error | ≤ ± 2% of full scale | |
Zero Drift | ≤ ± 0.02 ppm/day, ≤ ± 0.03 ppm/week | |
Span Drift | ≤ ± 2% of full scale/day, ≤ ± 2% of full scale/week | |
Response time (T90) | ≤ 180s | |
Gas flow rate | Sample gas : approx. 3.5L/min, reference gas : approx. 3.5L/min, span gas: approx. 3.5L/min Note: A delivery pressure of 50-100kPa is recommended for both sample and reference gas. | |
Analog output | Max. 2 channels isolated output (2 components) Select one from 0 to 1V, 0 to 10V, 0 to 16mA, 4 to 20mA or 0 to 20mA. Current output : Allowable load resistance 750Ω or less | |
Installation conditions | Ambient temperature | 0 to 40°C |
Ambient relative humidity | ≤85% | |
Dust | Less than environmental standard | |
Vibration | ≤ 0.29m/s², at ≤ 100Hz | |
External dimensions, weight | 430(W) x 221(H) x 555(D) mm (excluding protrusions), approx. 18kg | |
Power supply | 100 to 240V AC, ≤ ± 10% (max. voltage: 250V AC) | |
Power consumption | Approx. 100VA |